16943-5-0806 Page 1
INSTALLATION INSTRUCTIONS
AND
OWNER'S MANUAL
UNVENTED
ROOM HEATER
MODELS
BF-10-2 BF-20-2 BF-30-2
EFFECTIVE DATE
AUGUST 2006
WARNING: If not installed, operated and
maintained in accordance with the manufactur
-
er's instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and venti-
lation air must be provided. Refer to page 6.
WATER VAPOR: A BY-PRODUCT OF
UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately
one (1) ounce (30ml) of water for every 1,000
Btu (.3KW's) of gas input per hour. Refer to
page 6.
This appliance may be installed in an after-
market, permanently located, manufactured
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - OWNER'S MANUAL

16943-5-0806 Page 1INSTALLATION INSTRUCTIONSANDOWNER'S MANUALUNVENTED ROOM HEATERMODELS BF-10-2 BF-20-2 BF-30-2EFFECTIVE DATEAUGUST 2006WAR

Page 2 - TABLE OF CONTENTS

Page 10 16943-5-0806TO TURN OFF GAS TO APPLIANCE1. STOP! Read the safety information above.2. Set thermostat (gas control knob) to lowest setting

Page 3 - IMPORTANT SAFETY INFORMATION

16943-5-0806 Page 11Piezo Pilot Ignitor InstructionsDepressing the ignitor button completely causes a spark to occur at the pilot. To light the pilot

Page 4 - LP-GAS WARNING ODOR

Page 12 16943-5-0806The correct flame will be blue and will extend beyond the thermo-couple. The flame will surround the thermocouple just below the ti

Page 5 - SPECIFICATIONS

16943-5-0806 Page 13Glass Removal, Cleaning and Glass Replacement1. Remove chrome grill from reflector.2. Slide glass upward to remove glass from chr

Page 6 - Page 6 16943-5-0806

Page 14 16943-5-08061. Spark electrode does not produce spark.a. Spark electrode broken - replace.b. Ignitor wire may not be attached to spa

Page 7 - GAS SUPPLY

16943-5-0806 Page 15 INDEX PART NO. NO. DESCRIPTION INDEX PART NO. NO. DESCRIPTION 01 13347 CASING SIDE ASSEMBLY - LEFT (BF

Page 8 - CLEARANCES

Page 16 16943-5-0806PARTS VIEW

Page 9 - WALL MOUNT INSTALLATION

16943-5-0806 Page 17INSTALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the h

Page 10 - LIGHTING INSTRUCTIONS

Page 18 16943-5-0806. ...PARTS LISTWiringThe appliance, when installed, must be electrically grounded in accordance with local codes or, in the absenc

Page 11 - 16943-5-0806 Page 11

16943-5-0806 Page 19SERVICE NOTES

Page 12 - THERMOSTAT OPERATION

Page 2 16943-5-0806SECTION PAGEImportant Safety Information ...

Page 13 - APPLIANCE MAINTENANCE

Page 20 16943-5-0806Empire Comfort Systems, Inc.918 Freeburg Ave. Belleville, IL 62220PH: 618-233-7420 or 800-851-3153FAX: 618-233-7097 or 800-443-86

Page 14 - TROUBLESHOOTING

16943-5-0806 Page 3THIS IS A HEATING APPLIANCEDO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.• An unvented room heater having an i

Page 15 - HOW TO ORDER REPAIR PARTS

Page 4 16943-5-0806Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smel

Page 16 - PARTS VIEW

16943-5-0806 Page 5Qualified Installing AgencyInstallation and replacement of gas piping, gas utilization equip-ment or accessories and repair and ser

Page 17 - SRB-18T and SRB-30T

Page 6 16943-5-0806Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for eve

Page 18

16943-5-0806 Page 7The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the

Page 19 - SERVICE NOTES

Page 8 16943-5-0806SRS-18* and SRS-30 Floor Stand Installation 1. Align clearance holes on floor stand with screw holes on bottom of heater

Page 20

16943-5-0806 Page 9On Sheet Rock Wall 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) p