Empire Comfort Systems DVP42FP3 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Foyers Empire Comfort Systems DVP42FP3. Empire Comfort Systems DVP42FP3 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Page 117375-6-0705
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
WARNING: If not installed, operated and main-
tained in accordance with the manufacturers
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
state or local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
The Tahoe Direct Vent Zero Clearance
Gas Fireplace Heater
WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
-
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
-
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
● Immediately call your gas supplier
from a neighbors phone. Follow the
gas supplier's instructions.
● If you cannot reach your gas supplier,
call the fire department.
-
Installation and service must be
performed by a qualified installer, service
agency, or the gas supplier.
GAS-FIRED
DIRECT VENT
GAS FIREPLACE HEATER
MODEL SERIES
DVP42FP3(0,1,2,3)(N,P)-1 (MILLIVOLT STANDING PILOT)
DVP48FP3(0,1,2,3)(N,P)-1 (MILLIVOLT STANDING PILOT)
DVP42FP7(0,1,2,3)(N,P)-1 (INTERMITTENT PILOT)
DVP48FP7(0,1,2,3)(N,P)-1 (INTERMITTENT PILOT)
DVP42FP9(0,1,2,3)(N,P)-1 (REMOTE RF MODELS)
DVP48FP9(0,1,2,3)(N,P)-1 (REMOTE RF MODELS))
EFFECTIVE DATE
JULY 2005
UL FILE NO. MH30033
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - OWNER’S MANUAL

Page 117375-6-0705INSTALLATION INSTRUCTIONSANDOWNER’S MANUAL WARNING: If not installed, operated and main-tained in accordance with the manufactu

Page 2 - TABLE OF CONTENTS

Page 10 17375-6-0705Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow f

Page 3 - IMPORTANT SAFETY INFORMATION

Page 1117375-6-0705Note: For finishing to top of fireplace, refer to Figure 12.DVP42 DVP48"A" 37 3/4" 37 3/4""B" 43 3/8&qu

Page 4 - LP-GAS WARNING ODOR

Page 12 17375-6-0705Flush Wall InstallationFigure 12Combustible Surround InstallationFigure 13Attention: Cold climate installation recommendation: Whe

Page 5 - INTRODUCTION

Page 1317375-6-0705HORIZONTAL ONLY, STRAIGHT OUT THE BACKFigure 15VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALLCORNER INSTALLATION VERTICAL, 90° ELBO

Page 6 - FIREPLACE DIMENSIONS

Page 14 17375-6-0705VENTING FIREPLACE - TOP To Use the Vent Graph (Figure 19)1. Determine the height of the center of the horizontal vent pipe. Using

Page 7 - CLEARANCES

Page 1517375-6-0705Figure 21Examples of possible venting systems using two (2) 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is l

Page 8 - GAS SUPPLY

Page 16 17375-6-0705MAXIMUM HORIZONTALRUN WITH NO VERTICALRISE AND 90° ELBOWMAXIMUM HORIZONTALRUN WITH MINIMUMVERTICAL RISE AND90° ELBOWminimumFigure

Page 9 - & retainer when using

Page 1717375-6-0705EXAMPLES - TOP VENT RUNFigure 26Figure 27Figure 28

Page 10 - INSTALLATION

Page 18 17375-6-0705VENTING FIREPLACE - REARTo Use the Vent Graph (Figure 29)1. Determine the height of the center of the horizontal vent pipe

Page 11 - INSTALLATION (continued)

Page 1917375-6-0705EXAMPLES - REAR VENT RUNFigure 30Figure 31Figure 32Figure 33Model Maximum Pipe Length H1DVP42 24"DVP48 18"Model Maximum P

Page 12 - Page 12 17375-6-0705

Page 2 17375-6-0705TABLE OF CONTENTSImportant Safety Information ...

Page 13

Page 20 17375-6-0705Termination clearance for buildings with combustible and noncombustible exteriors.Vertical Sidewall InstallationsImportant! Minimu

Page 14 - VENTING FIREPLACE - TOP

Page 2117375-6-0705Figure 35A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum]B = clearance to window or do

Page 15 - Ceiling Level

Page 22 17375-6-0705Installing Vent Components (Figure 36)Begin the vent system installation by installing the first component, 90° elbow to the starti

Page 16 - Figure 25

Page 2317375-6-0705Installing Support Brackets (Figure 37)A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pip

Page 17 - EXAMPLES - TOP VENT RUN

Page 24 17375-6-0705 Figure 39Figure 41See Horizontal Termination Page 24 and Vertical Termination Page 25-26.FRAMING AND FINISHING (con

Page 18 - VENTING FIREPLACE - REAR

Page 2517375-6-0705INSTALLATION1. Unpack vent components and check that all items are included.2. Check to see that the vent spacer springs are lo

Page 19 - EXAMPLES - REAR VENT RUN

Page 26 17375-6-0705VERTICAL TERMINATIONLocate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive

Page 20 - TERMINATION CLEARANCES

Page 2717375-6-0705Reassembly and Resealing Vent Pipe SystemAttach vent pipe to inlet and outlet vent adaptor on fireplace in either the vertical or ho

Page 21 - VENT CLEARANCES

Page 28 17375-6-0705WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this

Page 22 - VENT SYSTEM IDENTIFICATION

Page 2917375-6-0705The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas con

Page 23 - FRAMING AND FINISHING

Page 317375-6-0705Section

Page 24 - HORIZONTAL TERMINATION

Page 30 17375-6-0705STANDING PILOT OPERATING INSTRUCTIONS REMOTE/OFF/ON SwitchThe fireplace is equipped with a REMOTE/OFF/ON switch. A wire harness is

Page 25

Page 3117375-6-0705STANDING PILOT WIRING DIAGRAMFigure 52(OPTIONAL) THERMOSTAT(OPTIONAL) WALL SWITCH

Page 26 - VERTICAL TERMINATION

Page 32 17375-6-0705STANDING PILOT LIGHTING INSTRUCTIONS4. Push in gas control knob slightly and turn clockwise to "OFF." Do not force.5.

Page 27 - Page 2717375-6-0705

Page 3317375-6-0705With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do

Page 28 - LOG PLACEMENT (3 LOG SET)

Page 34 17375-6-0705The intermittent pilot (120/24 volt system) is ON when the main burner is ON. When the main burner is OFF the intermittent pilot i

Page 29 - OPERATING INSTRUCTIONS

Page 3517375-6-0705FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fire or explosion may result causing

Page 30 - Page 30 17375-6-0705

Page 36 17375-6-0705GENERAL: All fireplaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fa

Page 31 - STANDING PILOT WIRING DIAGRAM

Page 3717375-6-0705Spark Generator PoweredFirstValve (Pilot)Operator OpensPilot burner lights.Modulesenses flame current.PILOT BURNER OPERATIONMODULES

Page 32 - Page 32 17375-6-0705

Page 38 17375-6-0705Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ign

Page 33 - Page 3317375-6-0705

Page 3917375-6-0705 INTERMITTENT PILOT TROUBLESHOOTING (continued)S8600H TROUBLESHOOTING GUIDENote:Before troubleshooting, familiarize yourself witht

Page 34

Page 4 17375-6-0705Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smel

Page 35 - Page 3517375-6-0705

Page 40 17375-6-0705RF STANDING PILOT OPERATING INSTRUCTIONSFunctions• Flame powered system• Flame powered flame modulation• Electronics integrated

Page 36 - Page 36 17375-6-0705

Page 4117375-6-0705FIRST USE OF TRANSMITTERStatus ActionBegin communication between transmitter and receiver/valve. Move LOCAL/REMOTE Switch to LOCAL

Page 37 - Page 3717375-6-0705

Page 42 17375-6-0705RF WIRING DIAGRAM WIRING DIAGRAM WITH BLOWERFigure 56STANDING PILOT LIGHTING INSTRUCTIONS

Page 38 - Page 38 17375-6-0705

Page 4317375-6-0705STANDING PILOT LIGHTING INSTRUCTIONSRF STANDING PILOT LIGHTING INSTRUCTIONS

Page 39 - S8600H TROUBLESHOOTING GUIDE

Page 44 17375-6-0705PLEASE NOTEIt is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up

Page 40 - Page 40 17375-6-0705

Page 4517375-6-0705PARTS VIEW15*1212789101112201913122322a21171816123456111427282931302433323440384239a36a37a415239b34333224302928273136b444637b333432

Page 41 - RF TRANSMITTER FUNCTIONS

Page 46 17375-6-0705INDEX NO. PART NUMBER DESCRIPTIONDVP42 DVP481R-7654 R-7654 FLUE INSULATION2 17426 17426 FLUE INSULATION RETAINER3R-7567 R-7567 INL

Page 42 - WIRING DIAGRAM WITH BLOWER

Page 4717375-6-0705FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATIONAttention: Install blower assembly before connecting gas inlet supply lineNote: J

Page 43 - Page 4317375-6-0705

Page 48 17375-6-0705FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION110 VOLT ACJUNCTION BOXWHITESPEEDCONTROLFANSWITCHGROUNDBLACKFAN1 FBB4 BLOWER ASSEM

Page 44 - MAINTENANCE AND SERVICE

Page 4917375-6-0705CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE B

Page 45 - PARTS VIEW

Page 517375-6-0705INTRODUCTIONInstructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer

Page 46 - PARTS LIST

Page 50 17375-6-0705The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond w

Page 47 - E BRACKET)

Page 5117375-6-0705Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts

Page 48 - 110 VOLT AC

Page 52 17375-6-0705SERVICE NOTESEmpire Comfort Systems, Inc.Nine Eighteen Freeburg Ave.Belleville, Illinois 62220-2623PH: 618-233-7420PH: 800-851-315

Page 49 - Page 4917375-6-0705

Page 6 17375-6-0705Figure 1SPECIFICATIONSDVP42 DVP48A 43"1092mm49"1245mmB 40"1016mm46"1168mmC 25 1/16"636 mm25 1/16"636

Page 50 - ACCESSORIES

Page 717375-6-0705Mantel Chart (Figure 3)Figure 3Clearances (Figure 4)Clearance from top front edge of fireplace to ceiling is 36"Clearance from s

Page 51 - SERVICE NOTES

Page 8 17375-6-0705Figure 6 The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas

Page 52

Page 917375-6-0705REAR VENT CONVERSIONNote: Discard insulation& retainer when usingvertical venting offVERTICAL VENTINGHORIZONTAL VENTINGFLUE INSU

Commentaires sur ces manuels

Pas de commentaire