Empire-comfort-systems PV-28SV50-B Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Four Empire-comfort-systems PV-28SV50-B. Empire Comfort Systems PV-28SV50-B User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Page 1
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
Mantis
P
ow
er
H
um
idifier
Burn
ers
Exhau
st
F
an
Blow
e
r
H
i
M
e
d
Low
Front
Re
ar
POWER-VENT
HIGH-EFFICIENCY
FIREPLACE WITH
BAY WINDOW
MODELS
PV-28SV50-B(N,P)-1
PV-28SV50-B2H(N,P)-1
PV-28SV55-(C,G)(N,P)-1
PV-28SV55-(C,G)2H(N,P)-1
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer’s in-
structions, this product could expose you to sub-
stances in fuel or from fuel combustion which can
cause death or serious illness.
Installer: Leave this manual with the
appliance.
Consumer: Retain this manual for future
reference.
— Donotstoreorusegasolineorotheramma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Donottrytolightanyappliance.
• Donottouchanyelectricalswitch;donot
use any phone in your building.
• Immediatelycallyourgassupplierfroma
neighbor’s phone. Follow the gas suppli-
er’s instructions.
• Ifyoucannotreachyourgassupplier,call
theredepartment.
— Installation and service must be performed
byaqualiedinstaller,serviceagencyorthe
gas supplier.
WARNING: If the information in these in-
structionsarenotfollowedexactly,areorex-
plosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
state or local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certiedkitisused.
EMPIRE
EMPIRE
Comfor t Systems
Attention: This appliance is NOT to be installed
in Canada.
Vue de la page 0
1 2 3 4 5 6 ... 55 56

Résumé du contenu

Page 1 - OWNER’S MANUAL

Page 1INSTALLATION INSTRUCTIONSANDOWNER’S MANUALMantisPowerHumidifierBurnersExhaustFanBlowerHiMedLowFrontRearPOWER-VENT HIGH-EFFICIENCY FIREPLACE WITH

Page 2 - TABLE OF CONTENTS

24820-1-0409Page 101. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide

Page 3 - IMPORTANT SAFETY INFORMATION

24820-1-0409 Page 11SPECIFICATIONSHeater with Pedestal and Single Flue Adaptor1 Flue Outlet 1 1/2” PVC Pipe2 Air Inlet3 Electric Cord4 3/8” Flare Conn

Page 4 - SOME POINTS TO REMEMBER

24820-1-0409Page 12SPECIFICATIONS - (continued)Figure 4Heater without pedestal1 Flue Outlet 1 1/2” PVC Pipe2 Air Inlet3 Electric Cord4 3/8” Flare Conn

Page 5 - 24820-1-0409 Page 5

24820-1-0409 Page 13SPECIFICATIONS - (continued)Figure 5Fireplace Insert with Mantel Surround with Slim Top Panel1 Flue Outlet 1 1/2” PVC Pipe2 Air In

Page 6 - GAS SUPPLY

24820-1-0409Page 14SPECIFICATIONS - (continued)Figure6Fireplace Insert with Mantel Surround with Short Top Panel1 Flue Outlet 1 1/2” PVC Pipe2 Air In

Page 7 - INTRODUCTION

24820-1-0409 Page 15CLEARANCE TO COMBUSTIBLESFreestanding ModelsFreestanding UnitsA Rear Wall to Heater 0” (2” Single Flue and 1 1/4” Direct Vent for

Page 8

24820-1-0409Page 16ROUGH FRAMING DIMENSIONSINSERT INTO MASONRY FIREPLACEA - 13 /34” MIN. CO-LINEAR 8 1/2” WHEN USING DIRECT VENTING PVVK-24

Page 9 - CLEARANCES FOR DIRECT VENT

24820-1-0409 Page 17WALL CLEARANCESFigure 14

Page 10 - CLEARANCES FOR SINGLE FLUE

24820-1-0409Page 18All LogsThe positioning of the logs is critical to the safe and clean opera-tion of this heater. Sooting and other problems may res

Page 11 - SPECIFICATIONS

24820-1-0409 Page 19VENT EXAMPLES FOR SINGLE FLUEMax Vent Run - 40 ft. Equivalent With Three (3) 90° ElbowsSpecialNote:Theventterminal90°elbowa

Page 12 - SPECIFICATIONS - (continued)

24820-1-0409Page 2TABLE OF CONTENTSImportant Safety Information ...

Page 13

24820-1-0409Page 20VENT EXAMPLES FOR SINGLE FLUE (cont.)Figure 19Single Flue - Vertical Vent RunH = 36’V = 1’(1) - 90° = 3’Total = 40’SINGLE FL

Page 14

24820-1-0409 Page 21Figure 23Single Flue - Vertical Vent Run with 45 degree elbowsVENT EXAMPLES FOR SINGLE FLUE (cont.)Figure 22MinimumExteriorGrad

Page 15 - CLEARANCE TO COMBUSTIBLES

24820-1-0409Page 22Available from Empire Comfort Systems, Inc.PVVK-CFAFLEXVENTKITThe ex vent kit is a exible vent hose that is 42” in length. The

Page 16 - INSERT INTO MASONRY FIREPLACE

24820-1-0409 Page 23Available from Empire Comfort Systems, Inc.INSTALL FOAM GASKETFLUE ADAPTORPLASTIC GASKETTHREADED CONNECTORAttach ue adaptor to ba

Page 17 - WALL CLEARANCES

24820-1-0409Page 24HORIZONTALEXAMPLESFORCOLINEARDIRECTVENTFigure 27Enhanced top view of Figure 26Figure26Max Vent Run - 40 ft. Equivalent With T

Page 18 - LOG SET DIAGRAM - A

24820-1-0409 Page 25VERTICAL EXAMPLES FOR COLINEAR DIRECT VENTFigure 28Calculation example of vent run maximum 40’Determining Minimum Vent Height Abov

Page 19 - 12” MIN

24820-1-0409Page 26VERTICAL EXAMPLES FOR COLINEAR DIRECT VENTSINGLE FLUEMODEL PVVK-SHCO-LINEARDIRECT VENT ADAPTERMODEL PVCA12XHEIGHTFLASHINGREQUIREDHE

Page 20 - MODEL #PVVK-SH

24820-1-0409 Page 27PVCAHORIZONTALCOLINEARDIRECTVENTADAPTORCOLINEAR ADAPTER1. Attach colinear adaptor to back of heater with two (2) sc

Page 21

24820-1-0409Page 28PVVTCTERMINATIONCAPVENTKITAvailable from Empire Comfort Systems, Inc.Termination CapVertical exhaust cap used with 1 1/2” PVC p

Page 22 - PVVK-CFAFLEXVENTKIT

24820-1-0409 Page 29PVCTCOLINEARTRANSITIONVENTKITAvailable from Empire Comfort Systems, Inc.Flat Roof or Chimney Application1. Attach plate to ch

Page 23 - THREADED CONNECTOR

24820-1-0409 Page 3IMPORTANT SAFETY INFORMATIONTHIS IS A HEATING APPLIANCEDO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.• Due to high

Page 24 - 24820-1-0409Page 24

24820-1-0409Page 30DIRECT VENT INSTALLATION INSTRUCTIONSFLUE CENTEREXTERIOR GRADEMANTELGAS SUPPLY12” (30.5cm)MIN.SURROUNDDO NOT GLUETHIS POINTDIRECT V

Page 25 - 24820-1-0409 Page 25

24820-1-0409 Page 31DIRECT VENT INSTALLATION INSTRUCTIONS (cont.)EXTERIOR GRADEFLUE CENTER1 1/4”(3.2cm)MIN.12”(30.5cm)MIN.FLOOR PROTECTIONFLOOR PROTEC

Page 26

24820-1-0409Page 32Available from Empire Comfort Systems, Inc.Step 1. Install foam gasket on back side of co-axial direct vent adaptor.Step 2. Attac

Page 27 - Colinear adaptor

24820-1-0409 Page 3345° ELBOW47.5”(1.2m)HorizontalVentingMaximum47.5”(1.2m)with45°elbow.45° elbow can be purchased from a local hardware store

Page 28 - Termination Cap

24820-1-0409Page 34GAS CONNECTION INSTALLATION INSTRUCTIONSGAS CONNECTION (Line Supply)A 3/8” Flair gas line connection is supplied in the heaterGAS S

Page 29 - Colinear Transition Plate

24820-1-0409 Page 35OPERATINGINSTRUCTIONSCHECKLISTBEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING CHECKLIST1. Read and u

Page 30 - 45° ELBOW

24820-1-0409Page 36LIGHTING INSTRUCTIONS1. Main Electrical power supply must always be switched on to the unit with the two burner switches in the of

Page 31 - 24820-1-0409 Page 31

24820-1-0409 Page 37LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EX-PL

Page 32 - 24820-1-0409Page 32

24820-1-0409Page 38FAN OPERATIONThe 3-speed main convection fan will automatically start approximately 3 to 5 minutes after the heater has warmed up.

Page 33

24820-1-0409 Page 39GAS CONVERSION INSTRUCTIONSWarning:Conversionmustbedonebyaqualiedservicetechnician.Mainburnerorices,frontburner

Page 34 - FLEXIBLE GAS

24820-1-0409Page 4SAFETY INFORMATION FOR USERS OF LP-GASPropane (LP-Gas) is a ammable gas which can cause res and explosions. In its natural state,

Page 35 - CHECKLIST

24820-1-0409Page 40GAS CONVERSION INSTRUCTIONSWarning:Conversionmustbedonebyaqualiedservicetechnician.Mainburnerorice(s)andnewgas c

Page 36 - LIGHTING INSTRUCTIONS

24820-1-0409 Page 41AUTOMATIC HUMIDIFIER OPERATIONMost gas heaters dry out the air in the room. The Mantis has in-geniously solved this problem wi

Page 37

24820-1-0409Page 42OPTIONAL CONTROLLERSSee your Mantis dealer for correct controller type. TEMPERATURE CONTROLLERSFRBTP Battery Operated Remote w/ Pr

Page 38 - FAN OPERATION

24820-1-0409 Page 43OPTIONAL CONTROLLERSR: 24 Volt HotW1: Heat Relay Stage 1 (Front burner)W2: Heat Relay Stage 2 (Rear burner)C: 24 Volt Common F

Page 39 - GAS CONVERSION INSTRUCTIONS

24820-1-0409Page 44WIRING(1) (2) BLACKBLACK (3) (4) REDYELLOW (5) (6) REDBLUE (7) (8) BROWNGREY (9) (10) REDRED (11) (12) BLACKBLACK (13) (14) REDRED

Page 40

24820-1-0409 Page 45GENERAL INFORMATIONOver Temperature Cut OutThe Mantis Power-Vent High-Efciency Fireplace is protected against overheating w

Page 41 - 24820-1-0409 Page 41

24820-1-0409Page 46MAINTENANCEFigure 55Front door removal drawingLOG SUPPORT PLATEBURNER PLATEREAR BURNERFRONT BURNERIGNITOR ASSEMBLYFLAME SENSORFigur

Page 42 - OPTIONAL CONTROLLERS

24820-1-0409 Page 47UNIT OPERATING FAULTSSERVICE AND INSTALLATION OF THE APPLIANCE SHOULDBECARRIEDOUTBYAUTHORIZEDPER-SONNEL ONLY.THE MAJOR CAUSE

Page 43

24820-1-0409Page 48MAIN CONVECTION FANThe main convection fan in the heater should be checked, ser-viced and cleaned annually by a qualied

Page 44 - WIRING DIAGRAM

24820-1-0409 Page 49PEDESTAL INSTALLATION INSTRUCTIONSOptional Pedestal Assembly Installation1. Remove pedestal assembly from carton. Handle pe

Page 45 - MAINTENANCE

24820-1-0409 Page 5REQUIREMENTSFORMASSACHUSETTSFor all side wall horizontally vented gas fueled equipment installed in every dwelling, building or s

Page 46

24820-1-0409Page 50PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 22868 REAR PANEL AS

Page 47 - LOG PLACEMENT

24820-1-0409 Page 51 49 22627 GAS LINE - REAR 50 22628 GAS LINE - FRONT 51 M174 GASKET 52 11269 GAS LINE BRACKET 53 R8886 COMPRESSION F

Page 48 - HEAT EXCHANGER

24820-1-0409Page 52PARTS VIEW14A569730283352115272428191112934293116201429262522178321336183523324B

Page 49 - 24820-1-0409 Page 49

24820-1-0409 Page 53PARTS VIEW6967728461504748535453516056554847805265394041423845468985868788817877736683769044434937827071647963625759107458756891

Page 50 - PARTS LIST

24820-1-0409Page 54WARRANTY TERMS Purchase Date: Dealer Name/Phone:Limited Ten-Year Heat Exchanger WarrantyEmpire promises to the owner that if the

Page 51

24820-1-0409 Page 55To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provid

Page 52 - PARTS VIEW

24820-1-0409Page 56EMPIREEMPIREComfor t SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about

Page 53

24820-1-0409Page 6Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code.Recommended Gas Pipe DiameterPipe

Page 54 - WARRANTY TERMS

24820-1-0409 Page 7QualiedInstallingAgencyInstallation and replacement of gas piping, gas utilization equip-ment or accessories and repair and serv

Page 55 - HOW TO ORDER REPAIR PARTS

24820-1-0409Page 8Model PV28SV50Input BTU/HR (KW/H) 19,000 Rear - 9,000 FrontHeight 25 1/8”Width 28 3/16”Depth 17 5/8”Gas Inlet (Pipe) 3/8” FlairElec

Page 56 - Comfor t Systems

24820-1-0409 Page 91. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide

Modèles reliés PV-28SV55

Commentaires sur ces manuels