Page 120101-0-0306
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
UNVENTED
GAS FIREPLACE
MODELS
VFP32FP(20,21)L(N,P)-1
VFP32FP(30,31)L(N,P)-1
VFP36FP(20,21)L(N,P)-1
VFP36FP(30,31)L(N,P)-1
EFFECTIVE DATE
MARCH 2006
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
This is an unvented gas-fired heater. It uses air (oxy-
gen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be
provided. Refer to page 7.
WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU's (.3KW's)
of gas input per hour. Refer to page 7.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
The Vail Vent-Free Gas Fireplaces
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - AND OWNER'S MANUAL

Page 120101-0-0306INSTALLATION INSTRUCTIONSAND OWNER'S MANUALUNVENTED GAS FIREPLACEMODELSVFP32FP(20,21)L(N,P)-1 VFP32FP(30,31)L(N,P)-1VFP36FP(2

Page 2 - TABLE OF CONTENTS

Page 10 20101-0-0306Minimum Wall and Ceiling Clearances (Figure 4)Sidewall Clearances: The clearance from the inside of the fireplace to any combustibl

Page 3 - IMPORTANT SAFETY INFORMATION

Page 1120101-0-0306Do not attach combustible material to the mantel of your fireplace. This is a fire hazard. Figure 6No greeting cards, stockings or or

Page 4 - LP-GAS WARNING ODOR

Page 12 20101-0-0306JUNCTION BOXASSEMBLYCFigure 8VFP32FP VFP36FPA34" 39"B29" 34"C17 3/8" 17 3/8"D31" 36"E22 7/

Page 5 - INTRODUCTION

Page 1320101-0-0306A black hood and trim kit is furnished with each model VFP(32,36)FP fireplace. The hood MUST be installed before the firepl

Page 6 - SPECIFICATIONS

Page 14 20101-0-03061. Place fireplace in framing opening.2. Using the four (4) nailing flanges provided with the fireplace, attach two (2) flanges on e

Page 7 - Page 720101-0-0306

Page 1520101-0-0306Placement of the glowing embers (rock wool) is very individual and light coverage of the areas indicated will provide your best eff

Page 8 - (continued)

Page 16 20101-0-0306Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set

Page 9 - GAS SUPPLY

Page 1720101-0-0306WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or

Page 10 - CLEARANCES

Page 18 20101-0-0306WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury

Page 11 - COMBUSTIBLE MATERIALS

Page 1920101-0-0306Figures 13 and 15 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flam

Page 12 - JUNCTION BOX

Page 2 20101-0-0306SECTION PAGEImportant Safety Information ...

Page 13 - PLANNING INSTALLATION

Page 20 20101-0-0306Figure 17 Warning: Never use needles, wires, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ru

Page 14 - Page 14 20101-0-0306

Page 2120101-0-0306If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the ga

Page 15 - Page 1520101-0-0306

Page 22 20101-0-0306 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.NOTE: SEE LOG INSTRUCTION MANU

Page 16 - Page 16 20101-0-0306

Page 2320101-0-0306Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts

Page 17 - TO TURN OFF GAS TO APPLIANCE

Page 24 20101-0-0306FBB4 Blower InstallationAttention: Install blower assembly before connecting gas inlet supply line.Note: Junction box on right sid

Page 18

Page 2520101-0-0306WiringThe appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local

Page 19 - PILOT FLAME CHARACTERISTICS

Page 26 20101-0-0306CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BU

Page 20 - IF ANY OF THE ORIGINAL WIRE

Page 2720101-0-0306SERVICE NOTES

Page 21 - TROUBLESHOOTING

Page 28 20101-0-0306Empire Comfort Systems, Inc.918 Freeburg Ave. Belleville, IL 62220PH: 618-233-7420 or 800-851-3153FAX: 618-233-7097 or 800-443-86

Page 22 - PARTS LIST

Page 320101-0-0306When used without adequate combustion and ventilation air, heater may give off CARBON MONOXIDE, an odorless, poisonous gas. D

Page 23 - HOW TO ORDER REPAIR PARTS

Page 4 20101-0-0306Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smel

Page 24 - Figure 19

Page 520101-0-0306Instructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer must have

Page 25 - Figure 21

Page 6 20101-0-0306ModelVFP32FP VFP36FPInput Maximum 32,000 36,000Minimum 22,000 25,000Minimum Firebox OpeningHeight without standoff32 3/4" 34

Page 26 - Brick Liner VPP32A and VPP36A

Page 720101-0-0306Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for eve

Page 27 - SERVICE NOTES

Page 8 20101-0-0306The space in the above example is a confined space because the actual BTU/Hr used is more than the maximum BTU/HR the space

Page 28

Page 920101-0-0306Check all local codes for requirements, especially for the size and type of gas supply line required.Recommended Gas Pipe DiameterPi