DIRECT VENT
GAS FIREPLACE HEATER
MODEL SERIES
MILLIVOLT STANDING PILOT
DVP42FP3(0,1,2,3)(N,P)-4
DVP48FP3(0,1,2,3)(N,P)-4
DIRECT IGNITION
DVP42FP5(0,1,2,3)N-1
DVP48FP5(0,1,2,3)N-1
INTERMITTENT PILOT
DVP42FP7(0,1,2,3)(N,P)-4
DVP48FP7(0,1,2,3)(N,P)-4
REMOTE RF MODELS
DVP42FP9(1,3)(N,P)-5
DVP48FP9(1,3)(N,P)-5
UL FILE NO. MH30033
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
WARNING: If not installed, operated and maintained
in accordance with the manufacturers instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certied
kit is used.
Direct Vent Zero Clearance Gas
Fireplace Heater
GAS-FIRED
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
re department.
Installation and service must be performed by a
qualied installer, service agency or the gas sup-
plier.
WARNING: If the information in these instructions
are not followed exactly, a re or explosion may
result causing property damage, personal injury or
loss of life.
WARNING
HOT GLASS
DO NOT TOUCH
NEVER
WILL
CAUSE BURNS.
GLASS
UNTIL COOLED.
ALLOW CHILDREN
TO TOUCH GLASS.
EMPIRE
EMPIRE
Comfor t Systems
Page 1
Vue de la page 0
1 2 3 4 5 6 ... 79 80

Résumé du contenu

Page 1 - OWNER’S MANUAL

DIRECT VENT GAS FIREPLACE HEATERMODEL SERIESMILLIVOLT STANDING PILOTDVP42FP3(0,1,2,3)(N,P)-4DVP48FP3(0,1,2,3)(N,P)-4DIRECT IGNITIONDVP42FP5(0,1,2,3)N-

Page 2 - TABLE OF CONTENTS

28649-2-0811Page 10Figure 7 The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas

Page 3

28649-2-0811 Page 11REAR VENT CONVERSIONConverting ue take-off to rear ventingWhen switching out the ue and inlet vent collars to run horizontally o

Page 4 - LP-GAS WARNING ODOR

28649-2-0811Page 12Framing and Finishing 1. Choose unit location.2. Frame in replace with a header across the top. It is important to allow for ni

Page 5

28649-2-0811 Page 13DVP42 DVP48"A" 37 3/4" 37 3/4""B" 43 3/8" 49 3/8""C" 19 7/8" 19 7/8"Fi

Page 6 - INTRODUCTION

28649-2-0811Page 14Flush Wall InstallationFigure 14Combustible Surround InstallationFigure 15Vent Runs (Figures 16, 17, 18, 19 and 20)In planning the

Page 7 - FIREPLACE DIMENSIONS

28649-2-0811 Page 15INSTALLATION (continued)HORIZONTAL ONLY, STRAIGHT OUT THE BACK"A" "B" MODEL 6"(152mm) 5 1/8"(130mm)

Page 8 - CLEARANCES

28649-2-0811Page 16To Use the Vent Graph (Figure 21)1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Si

Page 9 - LOCATING FIREPLACE

28649-2-0811 Page 17Figure 23Examples of possible venting systems using two (2) 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is

Page 10 - GAS SUPPLY

28649-2-0811Page 18MAXIMUM HORIZONTALRUN WITH NO VERTICALRISE AND 90° ELBOWMAXIMUM HORIZONTALRUN WITH MINIMUMVERTICAL RISE AND90° ELBOWminimumFigure 2

Page 11 - VENT SYSTEMS

28649-2-0811 Page 19Figure 28Figure 29Figure 3024”24” MINIMUMCLEARANCE TOCOMBUSTIBLESEXAMPLES - TOP VENT RUN

Page 12 - INSTALLATION

28649-2-0811Page 2Important Safety Information ...

Page 13 - INSTALLATION (continued)

28649-2-0811Page 20VENTING EXAMPLES WHEN USING DVA47 ADAPTORVertically Off Top of Fireplace OnlyFigure 31Figure 32Figure 33

Page 14

28649-2-0811 Page 21Installation InstructionsThis termination kit can only be used with Empire Comfort Systems direct vent replaces listed for use wi

Page 15

28649-2-0811Page 22PRE-INSTALLATION INFORMATION:Items Required For Installation:Tools Building SuppliesPhillips ScrewdriverHammerSaw and/or saber sawL

Page 16 - VENTING FIREPLACE - TOP

28649-2-0811 Page 231. Unpack vent components and check all items for shipping damage.2. For this venting system to operate as designed it i

Page 17

28649-2-0811Page 2410. With the ex vent assembly and the 48” long hard pipe com-ponents laid out on the oor, begin securing these parts to-gether.

Page 18

28649-2-0811 Page 2517. To attach the vent connections at the replace, be sure the 7” diameter adapter collar has been installed per step 3. Apply a

Page 19 - EXAMPLES - TOP VENT RUN

28649-2-0811Page 26Figure 40StormClearance toCombustiblesCollarExteriorRoofRoofFlashingRoof JackAdjustableAssembly4' Long Rigid PipeDirect VentFi

Page 20 - Figure 33

28649-2-0811 Page 27Vertical Flex Termination KitItem Number Item Description Repair Part No.Quantity Supplied1 4”/7” Vertical Termination Cap MF10003

Page 21 - IMPORTANT SAFETY INFORMATION

28649-2-0811Page 28 Acceptable vertical and horizontal vent run. Unacceptable vertical and horizontal vent run.Figure 41Venting Graph (Dimensions in

Page 22 - PRE-INSTALLATION INFORMATION:

28649-2-0811 Page 29Figure 42Figure 43Figure 44Figure 45Model Maximum Pipe Length H1DVP42 24"DVP48 24"Model Maximum Pipe Length H1DVP42 24&q

Page 23 - FLEX FLUE PIPE

28649-2-0811 Page 3DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLEDBefore enclosing the vent pipe assembly, operate the appliance to

Page 24 - SCREW (2)

28649-2-0811Page 30CAUTION: Sharp edges, use protective gloves when installing.Tools Needed for Installation:Sheet metal snips5/16” nut driverP

Page 25 - 1” (25mm)

28649-2-0811 Page 317. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168mm) diameter tube

Page 26 - 35 ft. Max

28649-2-0811Page 32Follow correct option according to venting method.Connecting Directly to FireplaceIf the air inlet and ue outlet tubes are to be c

Page 27 - Vertical Flex Termination Kit

28649-2-0811 Page 33INSTALLATION1. Unpack vent components and check that all items are included.2. Check to see that the vent spacer springs are l

Page 28 - VENTING FIREPLACE - REAR

28649-2-0811Page 34Termination clearance for buildings with combustible and noncombustible exteriors.Vertical Sidewall InstallationsImportant! Minimum

Page 29 - EXAMPLES - REAR VENT RUN

28649-2-0811 Page 35Figure 57A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum]B = clearance to window or do

Page 30 - DVA47 ADAPTOR

28649-2-0811Page 36Installing Vent Components (Figure 58)Begin the vent system installation by installing the rst Simpson Duravent component, 90° elb

Page 31 - OUTSIDE MOUNTING

28649-2-0811 Page 37Installing Vent Components (Figure 59)Begin the vent system installation by installing the rst Simpson Duravent component, 90° el

Page 32

28649-2-0811Page 38Installing Support Brackets (Figure 60)A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports

Page 33

28649-2-0811 Page 39Figure 64See Horizontal Termination Page 41 and Vertical Termination Pages 43 and 44.8" VENTING FRAMING AND FINISHING (contin

Page 34 - TERMINATION CLEARANCES

28649-2-0811Page 4Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must nd out if you can smell

Page 35 - VENT CLEARANCES

28649-2-0811Page 40Installing Support Brackets (Figure 65)A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports

Page 36 - VENT SYSTEM IDENTIFICATION

28649-2-0811 Page 41Figure 69See Horizontal Termination Page 41 and Vertical Termination on Pages 43 and 44.6 ⅝" VENTING FRAMING AND FINISHING (c

Page 37

28649-2-0811Page 42DVVK-5F FLEX VENT INSTRUCTIONSThe DVVK-5F FLEX VENT KIT includes the following components:• (1) Horizontal Termination Cap• (1)

Page 38 - OF WALL OPENING

28649-2-0811 Page 43Locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this c

Page 39

28649-2-0811Page 44Reassembly and Resealing Gas Accumulation Relief SystemGlass Frame Assembly and Combustion ChamberWhenever the glass frame assembly

Page 40

28649-2-0811 Page 45WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specically approved with this

Page 41 - HORIZONTAL TERMINATION

28649-2-0811Page 46The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the g

Page 42

28649-2-0811 Page 47STANDING PILOT OPERATING INSTRUCTIONS Remote/Off/On SwitchThe replace is equipped with a Remote/OFF/ON switch. A wire harness is

Page 43 - VERTICAL TERMINATION

28649-2-0811Page 48Figure 84(OPTIONAL) THERMOSTAT(OPTIONAL) WALL SWITCHSTANDING PILOT WIRING DIAGRAM

Page 44 - vertical

28649-2-0811 Page 491. Stop! Read the safety information above.2. Set REMOTE/OFF/ON switch to OFF.3. Turn off all electric power to the appliance

Page 45 - LOG PLACEMENT (4 LOG SET)

28649-2-0811 Page 5REQUIREMENTS FOR MASSACHUSETTSFor all side wall horizontally vented gas fueled equipment installed in every dwelling, building or s

Page 46 - OPERATING INSTRUCTIONS

28649-2-0811Page 50With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do

Page 47

28649-2-0811 Page 51DIRECT IGNITION WIRING DIAGRAMLED LIGHTLED LUMIÈREBLACK NOIRGREEN VERTWHITE BLANCRED ROUGEBLACK NOIRGAS VALVEVALVEDEGAZ(OPTIONAL)

Page 48 - STANDING PILOT WIRING DIAGRAM

28649-2-0811Page 52A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the oor because some gas is heavier than

Page 49 - TO TURN OFF GAS TO FIREPLACE

28649-2-0811 Page 531. Remove glass door and place away from the replace.2. Turn on gas shut off valve. Follow ignition procedure.3. If burner doe

Page 50

28649-2-0811Page 54The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and

Page 51 - OPTIONAL REMOTE CONTROL

28649-2-0811 Page 55DIRECT IGNITION PROPANE/LP GAS CONVERSIONModel AIR SHUTTER SETTINGSBURNER ORIFICEOpening "A" Propane/LP OriceDVP42 Full

Page 52 - TO TURN OFF GAS TO APPLIANCE

28649-2-0811Page 561. To wire Junction Box Receptacle, remove the tab on the side of the receptacle (hot side) to split receptacle. This will be requ

Page 53 - PURGE PROCEDURE

28649-2-0811 Page 571. Stop! Read the safety information above.2. Set the thermostat to lowest setting.3. Turn off all electric power to the applia

Page 54

28649-2-0811Page 58GENERAL: All replaces have been re-tested to check for proper operation. This includes, main burner ame, pilot ame, fan op-er

Page 55 - GAS TYPE SET FOR USE

28649-2-0811 Page 59where it is ignited by the pilot burner. The ame current also holds the safety lockout timer in the reset (normal) operating con

Page 56

28649-2-0811Page 6Instructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer must have ow

Page 57

28649-2-0811Page 60Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ign

Page 58 - Call Serviceman

28649-2-0811 Page 61INTERMITTENT PILOT TROUBLESHOOTING (continued)

Page 59 - (Main) opens

28649-2-0811Page 62INTERMITTENT PILOT TROUBLESHOOTING (continued)Green LED Status CodesGreen LED Flash Code (X + Y)aIndicates Next System Action Recom

Page 60

28649-2-0811 Page 63RF OPERATING INSTRUCTIONSRF VALVE OPERATION (AF-4040 Electronic Gas Valve system only)Please refer to the separate instructions fo

Page 61 - 28649-2-0811 Page 61

28649-2-0811Page 64RF MAINTENANCE INSTRUCTIONSMAINTENANCEMaintenance frequency must be determined individually for each application. Some consideratio

Page 62 - Green LED Status Codes

28649-2-0811 Page 65Figure 91RF WIRING DIAGRAMMOTORCOMM.GLIGHTSAUXFANMAINPILOTLearnMOTOR COMM.POWERIPIContinuousPilotOff/OnRemote/OffS IADJ.(GND)Stepp

Page 63 - RF OPERATING INSTRUCTIONS

28649-2-0811Page 66FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSIN

Page 64 - RF MAINTENANCE INSTRUCTIONS

28649-2-0811 Page 67Please NoteIt is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start

Page 65 - RF WIRING DIAGRAM

28649-2-0811Page 68DVP42FP(3,5,7,9) PARTS LISTIndex No.Part NumberDescriptionDVP42FP3 DVP42FP5 DVP42FP7 DVP42FP91 R7654 R7654 R7654 R7654 Insulation,

Page 66

28649-2-0811 Page 69DVP42FP(3,5,7,9) PARTS LIST38 16223 16223 16223 16223 Spring Retainer Assembly39 R10947 R8147 R721 - Wire Assembly40 R2708 - - - P

Page 67 - MAINTENANCE AND SERVICE

28649-2-0811 Page 7Figure 1DVP42 DVP48A43"1092mm49"1245mmB40"1016mm46"1168mmC25 1/16"636 mm25 1/16"636 mmD37 5/8"95

Page 68 - DVP42FP(3,5,7,9) PARTS LIST

28649-2-0811Page 70DVP48FP(3,5,7,9) PARTS LISTIndex No.Part NumberDescriptionDVP48FP3 DVP48FP5 DVP48FP7 DVP48FP91 R7654 R7654 R7654 R7654 Insulation,

Page 69

28649-2-0811 Page 71 Use Only Manufacturer’s Replacement Parts. Use of Any Other Parts Could Cause Injury Or Death.DVP48FP(3,5,7,9) PARTS LIST40 R2708

Page 70 - DVP48FP(3,5,7,9) PARTS LIST

28649-2-0811Page 72PARTS VIEW15*1212789101112201913122322211718161234561114272829313024333234404239363741513934333224302928273136573750534515262643INT

Page 71

28649-2-0811 Page 73To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provid

Page 72 - PARTS VIEW

28649-2-0811Page 74Attention: Install blower assembly before connecting gas inlet supply lineNote: Junction box on right side of replace must be p

Page 73 - HOW TO ORDER REPAIR PARTS

28649-2-0811 Page 75110 VOLT ACJUNCTION BOXWHITESPEEDCONTROLFANSWITCHGROUNDBLACKFAN1 FBB4 BLOWER ASSEMBLY COMPLETE2 R7649 FAN CONTROL3 R4192 SPEED CO

Page 74 - SEE NOTE*

28649-2-0811Page 76CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CO

Page 75 - 110 VOLT AC

28649-2-0811 Page 77The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond w

Page 76 - Figure 94

28649-2-0811Page 78Web Site www.empirecomfort.comEmpire Comfort Systems918 Freeburg AvenueBelleville, Illinois 62220-2623CLEARANCES TO COMBUSTIBLESGA

Page 77 - ACCESSORIES

28649-2-0811 Page 79Web Site www.empirecomfort.comEmpire Comfort Systems918 Freeburg AvenueBelleville, Illinois 62220-2623FRAMING DIMENSIONFIREBOX DI

Page 78 - Fireplace Heater

28649-2-0811Page 8Mantel Chart (Figure 4)Figure 3Clearances (Figure 5)Clearance from top front edge of replace to ceiling is 36"Clearance from s

Page 79

28649-2-0811Page 80EMPIREEMPIREComfor t SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about

Page 80 - Comfor t Systems

28649-2-0811 Page 9Figure 6Note: Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent sys