28649-2-0811 Page 11
REAR VENT CONVERSION
Converting ue take-off to rear venting
When switching out the ue and inlet vent collars to run horizontally
off the rear vent, the following steps must be taken.
1. Remove the inlet vent collar (8 screws) and ue collar (4 screws)
from the top of the replace, and set to the side.
2. Remove the inlet cover plate and ue cover plate located on
the back of the replace. These will be used to close the top
ue and inlet openings.
3. Insert the insulation retainer bracket and insulation into the top
ue pipe before reinstalling the ue cover plate over the top
ue with 4 screws.
4. Reinstall the inlet cover plate over the top inlet opening with 4
screws. See illustration above.
5. Install the ue collar assembly to the rear ue with 4 screws.
6. Install the inlet vent collar to the rear of the replace with 8
screws.
7. This completes the conversion for a rear vent application.
Note: For top vented installations, the insulation and retainer are
to be removed from the ue pipe and discarded.
VENT SYSTEMS
The following vent systems are acceptable for use with the
DVP (42,48) series replaces:
Simpson Duravent® GS 5" - 8", Refer to Page 37.
American Metal Products 5" - 8"
Selkirk Direct-Temp® 5" - 8"
Security Secure Vent® 5" - 8"
Empire Flexvent Kit DVVK-5F, Refer to Page 42.
The following vent systems are acceptable for use with the DVA-47
adaptor vertically off top of replace only:
Simpson Duravent
®
GS 4" - 6⅝", refer to page 36.
American Metal Products 4" - 6⅝"
Selkirk Direct-Temp® 4" - 6⅝"
Security Secure Vent® 4" - 6⅝"
Empire Horizontal Round Termination Kit DVVK-4RE, refer to page
30.
Empire Flexvent Kit DVVK-4F, refer to page 33.
Empire Direct Vent Kit DVVK-4FV, refer to page 21.
Note: Discard insulation
& retainer when using
vertical venting off
VERTICAL VENTING
HORIZONTAL VENTING
FLUE INSULATION
INSULATION
RETAINER
INLET VENT COLLAR
INLET VENT COLLAR
FLUE OUTLET
COLLAR
FLUE COVER PLATE
(See note above)
INLET VENT
COVER PLATE
FLUE COVER PLATE
INLET VENT
COVER PLATE
Note:Itis recommended that the
flue cover plate tab be pulled
outward prior to removal.
This will ensure that the plate
is not accidentally dropped
inside the rear air chamber.
Note: Discard insulation
& retainer when venting off
top of fireplace.